Spesifikasi Bante900P-CN
Bante900P-CN (PH Meter)
High-performance multiparameter water quality meter contains the 8 measurement modes, the meter is suitable for measuring the pH, ORP, ion concentration, conductivity, TDS, salinity, resistivity and dissolved oxygen.
pH Mode:
• Portable multiparameter water quality meter is equipped with a large backlit LCD display.
• 1 to 5 points push-button calibration with auto-buffer recognition.
• Selectable pH buffer group (USA/NIST/DIN) or using the custom calibration solutions.
• Automatic electrode diagnosis with pH slope and offset display.
ORP Mode:
• 1 point offset calibration allows adjusting the displayed value to a known standard.
• Relative and absolute millivolt modes provide the reliable ORP measurements.
Ion Mode:
• 2 to 5 points calibration, including the 8 concentration points can be selected.
• Automatically recognizes the ion selective electrode, does not need to specify type of ion.
• Direct ion concentration readout simplifies the measurement process.
• Selectable concentration units, including the ppm, mg/L and mol/L.
Conductivity/TDS/Salinity/Resistivity Modes:
• 1 to 5 points calibration, automatically recognizes the conductivity standard solutions.
• Selectable cell constant (K=0.1/1/10), reference temperature (20/25°C), TDS factor, linear
and pure water compensations, seawater and practical salinity measurement modes.
Dissolved Oxygen Mode:
• 1 or 2 points calibration using the air-saturated water or zero oxygen solution.
• Salinity and barometric pressure compensations ensure the reliable DO measurements.
Other Features:
• Automatic Temperature Compensation provides accurate reading over the entire range.
• Calibration Due Alarm prompts user to calibrate the meter regularly.
• Stability indicator shows when a measurement is recognized as stable.
• Auto-Hold feature senses and locks the measurement endpoint.
• Battery indicator shows the remaining battery capacity.
• Auto-Power Off effectively conserves battery life.
• Calibration report provides the details for checking the electrode performance.
• Setup menu allows setting the 15 parameters, including the number of calibration points,
stability criteria, temperature unit, date and time, etc.
• Reset feature automatically resumes all settings back to factory default options.
• Expanded memory stores and recalls up to 500 data sets.
• Stored readings can be transferred into the computer by USB communication interface.
• Multi-mode power scheme (batteries, power adapter and USB port) ensures that use the
meter smoothly.
Specifications
Model | | Bante900P |
pH | | |
Range | | -2.000~20.000pH |
Accuracy | | ±0.002pH |
Resolution | | 0.1, 0.01, 0.001pH, selectable |
Calibration Points | | 1 to 5 points |
pH Buffer Options | | USA, NIST, DIN or Custom |
mV | | |
Range | | ±1999.9mV |
Accuracy | | ±0.2mV |
Resolution | | 0.1, 1mV, selectable |
Calibration Points | | 1 point |
Measurement Modes | | Relative or Absolute mV |
Ion | | |
Range | | 0.001~19999 (Deponding on the range of ISE) |
Accuracy | | ±0.5% F.S (Monovalent), ±1% F.S (Divalent) |
Resolution | | 0.001, 0.01, 0.1, 1 |
Calibration Points | | 2 to 5 points (0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000) |
Measurement Units | | ppm, mg/L, mol/L, mmol/L |
Conductivity | | |
Range | | 0.01~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm |
Accuracy | | ±0.5% F.S |
Resolution | | 0.001, 0.01, 0.1, 1 |
Calibration Points | | 1 to 5 points |
Calibration Solutions | | 10µS/cm, 84µS/cm,1413µS/cm,12.88mS/cm,111.8mS/cm |
Temperature Coefficient | | 0.0~10.0%/°C |
Compensation Modes | | Linear or Pure water |
Cell Constant | | K=0.1, 1, 10 or Custom |
Reference Temperature | | 20°C or 25°C |
TDS | | |
Range | | 0~10.00, 100.0, 1000ppm, 10.00, 100.0ppt (Max. 200ppt) |
Accuracy | | ±1% F.S |
Resolution | | 0.01, 0.1, 1 |
TDS Factor | | 0.1~1.0 (Default 0.5) |
Salinity | | |
Range | | 0.00~80.00ppt, 0.00~42.00psu |
Accuracy | | ±1% F.S |
Resolution | | 0.01 |
Measurement Modes | | Practical salinity (psu) or Natural seawater (ppt) |
Resistivity | | |
Range | | 0.00~20.00MΩ |
Accuracy | | ±1% F.S |
Resolution | | 0.01, 0.1, 1 |
Dissolved Oxygen | | |
DO Range | | 0.00~20.00mg/L |
Accuracy | | ±0.2mg/L |
Resolution | | 0.1, 0.01mg/L, selectable |
% Saturation of Oxygen | | 0.0~200.0% |
Accuracy | | ±2.0% |
Resolution | | 0.1, 1% |
Calibration Points | | 1 or 2 points |
Pressure Correction | | 60.0~112.5kPa, 450~850mmHg |
Salinity Correction | | 0~50g/L |
Temperature | | |
Range | | 0~105°C, 32~221°F |
Accuracy | | ±0.5°C |
Resolution | | 0.1°C, 0.1°F |
Calibration Points | | 1 point |
Calibration Range | | Measured value ±10°C |
General | | |
Temperature Compensation | | 0~100°C, 32~212°F, Manual or Automatic |
Data Hold | | Manual or Auto-Endpoint |
Stability Criteria | | Low or High |
Calibration Due Alarm | | 1 to 31 days or Off |
Power Off | | Manual or Automatic (10, 20, 30 minutes) |
Reset Function | | Yes |
Memory | | Stores up to 500 data sets |
Output | | USB communication interface |
Connector | | BNC, 6-pin mini plug |
Display | | LCD |
Power | | 3×1.5V AA batteries or DC5V power adapter |
Battery Life | | Approximately 150 hours (Turn off the backlit) |
Dimensions | | 170(L)×85(W)×30(H)mm |
Weight | | 300g |